Best Supplier of Molecular Products

Starch Assay Kit Cell Biolabs Prezzo

Lab Reagents

Human IgG antibody Laboratories manufactures the starch assay kit cell biolabs prezzo reagents distributed by Genprice. The Starch Assay Kit Cell Biolabs Prezzo reagent is RUO (Research Use Only) to test human serum or cell culture lab samples. To purchase these products, for the MSDS, Data Sheet, protocol, storage conditions/temperature or for the concentration, please contact Cell Biolabs. Other Starch products are available in stock. Specificity: Starch Category: Assay Group: Kit Cell

Kit Cell information

Glutamate Assay Kit

STA-674 200 assays
EUR 616.8
Description: Glutamate is a non-essential amino acid that serves as an important neurotransmitter in the mammalian brain and has a key role in cellular metabolism. Excess glutamate levels in the brain can cause cell injury and death, leading to neurological diseases. Our Glutamate Assay Kit is a quantitative, fluorometric assay that uses glutamate specific enzymes to generate hydrogen peroxide. An ADHP probe is oxidized by hydrogen peroxide to generate fluorescent Resorufin, which correlates to the level of glutamate in the sample. Glutamate levels in an unknown sample are calculated based on a glutamate standard curve.

Hydroxyproline Assay Kit

STA-675 96 assays
EUR 616.8
Description: The Hydroxyproline Assay Kit is a quantitative colorimetric assay for measuring the hydroxyproline concentration in protein samples, including collagen where it is found almost exclusively.

CytoSelect 48-Well Cell Contraction Assay Kit

CBA-5021 48 assays
EUR 762
Description: Cell Biolabs? Cell Contraction Assays (Floating Matrix Model) provide a simple, in vitro system to assess cell contractivity and screen cell contraction mediators. The proprietary Cell Contraction Plate eliminates the matrix releasing step of the conventional contraction assay, providing a faster, higher-throughput method to assess cell contraction.

Collagen-based Cell Contraction Assay

CBA-201 24 assays
EUR 582
Description: Cell Biolabs? Collagen-based Contraction Assay Kit provides a simple system to assess cell contractivity in vitro and screen cell contraction mediators. Each kit provides sufficient quantities to perform up to 24 assays in a 24-well plate. The kit can be also used in culturing cells in 3D collagen matrix.

CytoSelect MTT Cell Proliferation Assay

CBA-252 960 assays
EUR 490.8
Description: Cell Biolabs? CytoSelect MTT Cell Proliferation Assay provides a colorimetric format for measuring and monitoring cell proliferation.  The kit contains sufficient reagents for the evaluation of 960 assays in 96-well plates or 192 assays in 24-well plates.  Cells can be plated and then treated with compounds or agents that affect proliferation.  Cells are then detected with the proliferation reagent, which is converted in live cells from the yellow tetrazole MTT to the purple formazan form by a cellular reductase (Figure 1).  An increase in cell proliferation is accompanied by an increased signal, while a decrease in cell proliferation (and signal) can indicate the toxic effects of compounds or suboptimal culture conditions.  The assay principles are basic and can be applied to most eukaryotic cell lines, including adherent and non-adherent cells and certain tissues.  This cell proliferation reagent can be used to detect proliferation in bacteria, yeast, fungi, protozoa as well as cultured mammalian and piscine cells.

Lactate Assay Kit (Colorimetric)

MET-5012 100 assays
EUR 540
Description: Our Lactate Assay Kit measures L-lactate in biological samples. Lactate is first oxidized by lactate oxidase, yielding pyruvate and hydrogen peroxide. The hydrogen peroxide released from this reaction is specifically detected by either a colorimetric or fluorometric probe in a 1:1 ratio. Lactate levels in unknown samples are determined based on a lactate standard curve.

Lactate Assay Kit (Fluorometric)

MET-5013 100 assays
EUR 540
Description: Our Lactate Assay Kit measures L-lactate in biological samples. Lactate is first oxidized by lactate oxidase, yielding pyruvate and hydrogen peroxide. The hydrogen peroxide released from this reaction is specifically detected by either a colorimetric or fluorometric probe in a 1:1 ratio. Lactate levels in unknown samples are determined based on a lactate standard curve.

NAD+/NADH Assay Kit

MET-5014 100 assays
EUR 686.4
Description: Our NAD+/NADH Assay Kit detects NAD+ and NADH in cell and tissue lysates. Total NAD+/NADH can be detected or samples can be treated with an acid or base treatment to specifically detect NAD+ or NADH. This assay uses an enzymatic cycling reaction that reduces NAD+ to NADH, which then reacts with a colorimetric probe and is detected with a spectrophotometric plate reader at 450nm. NAD+/NADH levels in unknown samples are calculated based on the provided NAD+ standard curve.

Soluble Collagen Assay Kit

MET-5016 96 assays
EUR 644.4
Description: Our Soluble Collagen Assay Kit detects soluble collagen in cell and tissue lysates. This assay uses a Sirius Red Reagent to stain the triple helix structure of collagen that has been dried onto the wells of a 96-well plate. The collagen is washed with an Acidic Reagent and the stain is eluted with a Basic Reagent, which is then transferred to a new plate and read colorimetrically between 540nm-560nm. The amount of soluble collagen in samples is determined based on a provided collagen standard curve.

BCG Albumin Assay Kit

MET-5017 250 assays
EUR 498
Description: Our BCG Albumin Assay utilizes a proprietary bromocresol green (BCG) formulation for the detection of albumin in biological samples. BCG forms a color complex after 5 minutes when bound to albumin and is detected colorimetrically between 570-670nm. The amount of albumin in samples is determined based on a provided albumin standard curve.

NADP+/NADPH Assay Kit

MET-5018 100 assays
EUR 686.4
Description: Our NADP+/NADPH Assay Kit detects NADP+ and NADPH in cell and tissue lysates. Total NADP+/NADPH can be detected or samples can be treated with an acid or base treatment to specifically detect NADP+ or NADPH. This assay uses an enzymatic cycling reaction that reduces NADP+ to NADPH, which then reacts with a colorimetric probe and is detected with a spectrophotometric plate reader at 450nm. NADP+/ NADPH levels in unknown samples are calculated based on the provided NADP+ standard curve.

Glycogen Assay Kit (Colorimetric)

MET-5022 100 assays
EUR 574.8
Description: Our Glycogen Assay Kit (Fluorometric) measures glycogen in serum, plasma, urine, lysates, and cell culture supernatants. First, glycogen is broken down into glucose monomers by amyloglucosidase. Glucose is then oxidized by glucose oxidase, producing D-gluconic acid and hydrogen peroxide. The hydrogen peroxide reacts specifically with the kit?s Fluorometric Probe and is detected at ex. 530-570 nm/em. 590-600 nm. Glycogen levels in unknown samples are determined based on the provided glycogen standard curve.

Glycogen Assay Kit (Fluorometric)

MET-5023 100 assays
EUR 574.8
Description: Our Glycogen Assay Kit (Colorimetric) measures glycogen in serum, plasma, urine, lysates, and cell culture supernatants. First, glycogen is broken down into glucose monomers by amyloglucosidase. Glucose is then oxidized by glucose oxidase, producing D-gluconic acid and hydrogen peroxide. The hydrogen peroxide reacts specifically with the kit?s Colorimetric Probe and is detected with a spectrophotometric plate reader at 540-570nm. Glycogen levels in unknown samples are determined based on the provided glycogen standard curve.

Phosphatidylglycerol/Cardiolipin Assay Kit

MET-5024 100 assays
EUR 602.4
Description: Our Phosphatidylglycerol/Cardiolipin Assay Kit measures both phosphatidylglycerol and cardiolipin in cell lysate samples by a coupled enzymatic reaction system. First, lipase is used to hydrolyze phosphatidylglycerol and cardiolipin to glycerol, which is then phosphorlyated by glycerol kinase to yield glycerol-3-phosphate. Next, the glycerol-3-phosphate product is oxidized by glycerol-3-phosphate oxidase (GPO), producing hydrogen peroxide. The hydrogen peroxide released from this reaction reacts specifically with the kit?s Fluorometric Probe and is detected at ex. 530-560 nm/em. 585-595 nm. Phosphatidylglycerol and cardiolipin levels in unknown sampled are determined based on the provided cardiolipin standard curve.

Homocitrulline/Citrulline Assay Kit

MET-5027 100 assays
EUR 609.6
Description: Our Homocitrulline/Citrulline Assay Kit detects total homocitrulline/citrulline in plasma, serum, urine, or cell and tissue lysates. Samples are first treated with sodium dodecyl sulfate (SDS) and proteinase K to release free homocitrulline/citrulline residues. Assay reagents are then added, which react with homocitrulline and citrulline to produce a chromophore. The absorbance is read at 540-560nm and the levels of homocitrulline/citrulline are determined based on the provided standard curve.

DAG (Diacylglycerol) Assay Kit

MET-5028 100 assays
EUR 609.6
Description: Our DAG (Diacylglycerol) Assay Kit measures diacylglycerol in cell lysate samples by a coupled enzymatic reaction system. First, kinase is used to phosphorylate DAG in samples, yielding phosphatidic acid. Next, lipase is used to hydrolyze phosphatidic acid to glycerol-3-phosphate. The glycerol-3-phosphate product is then oxidized by glycerol-3-phosphate oxidase, producing hydrogen peroxide. The hydrogen peroxide released from this reaction reacts specifically with the kit?s Fluorometric Probe and is detected at ex. 530-560 nm/em. 585-595 nm. DAG levels in unknown samples are determined based on the provided DAG standard curve.

Choline Assay Kit (Fluorometric)

MET-5042 96 assays
EUR 609.6
Description: Cell Biolabs? Choline Assay Kits are simple assays that measure the amount of choline present in a variety of sample types in a convenient 96-well microtiter plate format.  Each kit provides sufficient reagents to perform up to 96 assays, including blanks, acetylcholine standards and samples.  Sample choline concentrations are determined by comparison with a known choline standard and measured on a fluorescence plate reader.